Revision log
Website changes are recorded on IQ-DOC-001. One line per document revision. Calculator labels are separate and stay indicative.
0433 597 205IQEG / RESOURCES
Short practice notes used on industrial jobs. They are guidance, not a Standard, and not a substitute for project-specific engineering.
Website changes are recorded on IQ-DOC-001. One line per document revision. Calculator labels are separate and stay indicative.
Start with what can be seen, measured and photographed. Record the load path, interfaces, access and what the drawings get wrong. An information-gap register is more useful than a guessed as-built.
IQEG catalogue properties omit root fillets. Use mill tables (OneSteel / Liberty / ASI) for certified section properties. The drawings show d, bf, tf, tw and r so the geometry can be checked.
AS/NZS 1554.1 category and throat govern capacity. Minimum and maximum fillet size follow the thinner part and the procedure. The weld-group tool is a line-group solver, not a connection catalogue.
Walkway ≤ 7°, ramp 7–20°, stair 20–45°, ladder 70–90°. Top rail 900–1100 mm, openings ≤ 450 mm, toe board 100 mm. The quick-reference tables are indicative — the current Standard and the occupancy in AS/NZS 1170.1 govern.
The elastic point method shares N, Vx, Vy, Mxx, Myy and Mz onto bolts as points. Compression is counted in the N distribution; the tension check uses max(N, 0). End plates with a contact block, prying and T-stub behaviour need a different model. IQ-CAL-013 is a group solver, not a connection catalogue.
Every calculator on this site is indicative. Starting labels are 1.03, 1.04 or 1.05. Check mill tables, weld procedures, bolt assembly certificates and manufacturer data before use. IQEG will prepare a project-specific package on engagement.
IQ ENGINEERING GROUP