0433 597 205

IQEG / ENGINEERING LAB

Column base plate

IQ-CAL-015REV 1.05NOT A CERTIFICATE
IQEG

IQEG CALCULATION LAB

Column base plate

IQ-CAL-015 · Rev 1.05 Indicative · 17/11/2026 · Not a certificate

INPUTS + RESULTSUNITS AS TABULATED

IQ Engineering Group · Sydney · IQ-CAL-015 · Column base plate · millimetres, kN, kNm, MPa unless noted

DISCLAIMER
Column
Base plate

fy used for this thickness is 250 MPa. Editing the length updates the Y edge. Editing the width updates the X edge.

Anchor bolts
Concrete and grout
Loads

G is dead, Q is live, Wu is ultimate wind. Positive axial load is compression.

GQWu
P kN
Mx kNm
My kNm
Vx kN
Vy kN
GQWu
P kN
Mx kNm
My kNm
Vx kN
Vy kN
GQWu
P kN
Mx kNm
My kNm
Vx kN
Vy kN
Method and factors
Report heading — stays in this browser

Arrangement

YYT1T2B1B26040060520 (N)100160100360 (B)d = 254tension rowcompression sideXPLAN 1:5
Plan. Hole-centre chains. Pitch is the bolt spacing along X. Row spacing is along Y.PL 360x520x40 Gr250 · 250UC72.9 · 4 x Ø26 holes, M24 8.8 · 8 fillet SP
60400 (row spacing)60520 (N)d = 254tp = 40tg = 35 grout8E48 · SP · all roundP* = 607.5 kNM*x = 33.8 kNmT = 0.0 kNper bolt (B1, B2)−Y+Ytension sidecompression sideELEVATION A–A 1:5Embedment not designed (shown broken)
Elevation A–A. Plate and grout are separate dimensions. The fillet is the weld symbol. Embedment is not designed (shown broken).
P* = 607.5 kNM*x = 33.8 kNmq = 6.05 MPaC = 607.5 kNc = 520.0f = 200.0N/2 = 260LINEAR: ELASTIC, CRACKED SECTION−Y+Y(bolts slack)
P* = 607.5 kNM*x = 33.8 kNmq = 4.46 MPaC = 607.5 kNY = 408.9f = 200.0N/2 = 260PLASTIC: RECTANGULAR BLOCK AT φfb−Y+Y(bolts slack)
Bearing free bodies for this drawing case. Linear block and plastic block.

Results

AS/NZS 1170.0 cl. 4.2.2. 1.35G, 1.20G+1.50Q, 1.20G+Wu+0.40Q and 0.90G+Wu. Wind is run both ways. Design checks pass.

Case Case 1 · 1.35G: P* 607.5 kN · Mx* 33.8 · My* 8.1 kNm · Vx* 27.0 · Vy* 13.5 kN

Case Case 1 · 1.2G+1.5Q: P* 540.0 kN · Mx* 30.0 · My* 7.2 kNm · Vx* 24.0 · Vy* 12.0 kN

Case Case 1 · 1.2G+Wu+ψQ: P* 540.0 kN · Mx* 30.0 · My* 7.2 kNm · Vx* 24.0 · Vy* 12.0 kN

Case Case 1 · 0.9G+Wu: P* 405.0 kN · Mx* 22.5 · My* 5.4 kNm · Vx* 18.0 · Vy* 9.0 kN

Plate thickness — bearingDemand t 32.3 mmCapacity t 40.0 mm provided0.65PASSCase 1 · 1.35G
  1. m, n, λn'

    Cantilever past the column. 0.95d and 0.80bf on UB and UC. 0.95d and 0.95b on an SHS. The plate across the inside of a tube is not checked. λn' is the I-section web term.

    l = 139.4 mm, q = 6.05 MPa
  2. AS 4100 φMs

    Required thickness from M = q l² / 2.

    t required 32.3 mm, t provided 40.0 mm, fy 250 MPa
  3. Governing bearing stress

    Bearing-side plate bending uses the greater of the linear peak and the plastic block. The linear distribution governs. The simplified bolt-group method does not replace this check.

    q linear 6.05 MPa, q plastic 4.46 MPa
Fillet weld around the columnDemand 814.13 N/mmCapacity 1,303.34 N/mm0.62PASSCase 1 · 1.35G
  1. AS 4100:2020 cl. 9.6.3.10

    One fillet around the section profile. Elastic line group, the same distribution as the weld tool. The long-lap factor kr is kept at 1.

    Lw = 1,507 mm, tt = 5.66 mm, fuw = 480 MPa
  2. φ × 0.6 fuw tt

    Demand is the peak force per unit length from the full action. Bearing is not deducted.

    f = 814.1 N/mm, capacity 1,303.3 N/mm, SP
Bearing pressure — linearDemand 6.05 MPaCapacity 17.28 MPa0.35PASSCase 1 · 1.35G
  1. Statics

    Compression is positive. Inside the kern the stress is P/A ± M y / I. Once the no-tension block cannot balance the load, the bolts are (Es/Ec) As on a cracked section.

    P* = 607.50 kN, Mx* = 33.75 kNm, My* = 8.10 kNm, mode full
  2. σ = P/A ± M y / I

    Peak and minimum bearing stress of the linear field.

    σmax = 6.05 MPa, σmin = 0.44 MPa, A = 187,200 mm²
  3. AS 3600-2018 cl. 12.6

    Design bearing stress φ × 0.9 f'c √(A2/A1), capped at φ × 1.8 f'c.

    f*b = 17.28 MPa, utilisation 0.35
Bearing pressure — plasticDemand 4.46 MPaCapacity 17.28 MPa0.26PASSCase 1 · 1.35G
  1. AISC DG1 rectangular block

    While a compressive resultant is inside e_crit the block is the rectangle centred on the load and the bolts are slack. Past e_crit, and also under net uplift with a moment, the block is at the bearing strength and the bolt tension is C − P. A biaxial resultant uses the larger of the two uniaxial mechanisms. If that quadratic has no root, the elastic bolt forces are used.

    mode rectangle, q = 4.46 MPa, P* = 607.50 kN
  2. AS 3600-2018 cl. 12.6

    The same design bearing stress as the linear check.

    f*b = 17.28 MPa on 360 × 520 mm
  3. Moments

    Actions used for this block.

    Mx* = 33.75 kNm, My* = 8.10 kNm
Bolt shearDemand 7.55 kNCapacity 133.50 kN0.057PASSCase 1 · 1.35G
  1. Equal share

    Vx and Vy are combined, then shared. Friction, when selected, is μ times this combination's axial compression, not the compression of a different combination.

    V* = 30.19 kN, μC = 0.00 kN, P* compression 607.50 kN, each bolt 7.55 kN
  2. AS 4100:2020 cl. 9.2.2.1

    One shear plane, threads in the plane. AS 4100 uses the core area Ac and krd = 0.83 for 10.9. In AS 3990 mode the factor on fu As is an editable default, to be confirmed.

    φVf or Vall = 133.50 kN
Ply bearingDemand 7.55 kNCapacity 787.20 kN0.010PASSCase 1 · 1.35G
  1. AS 4100:2020 cl. 9.2.2.4

    Bearing of the plate under the bolt. fu is the AS/NZS 3678 value for the grade (410, 430 or 450 MPa). The lesser of 3.2 df and the edge distance, times the plate thickness and fu.

    φVb = 787.20 kN, ae = 60.0 mm, fu = 410 MPa
Bolt tension and shearDemand Nt 0.00 kN, V 7.55 kNCapacity 234.4 kN tension, 133.5 kN shear0.003PASSCase 1 · 1.35G
  1. AS 4100:2020 cl. 9.2.2.3

    Most loaded bolt. Shear is the same in every bolt. The AS 3990 linear interaction is an editable-method default, to be confirmed.

    (V/φVf)² + (Nt/φNtf)² = 0.003
Bolt tension — most loadedNot applicable: no uplift in any caseN/A
  1. Bolt tension

    Each distribution reports a bolt force. The check uses the greater of the two.

    T1: linear 0.00 kN, plastic 0.00 kN, used 0.00 kN
  2. AS 4100:2020 cl. 9.2.2.2

    Tension capacity of one bolt. In AS 3990 mode the factor on fu As is an editable default, to be confirmed.

    φNtf or Nall = 234.39 kN
Plate thickness — bolt tensionNot applicable: no uplift in any caseN/A
  1. 45° plate width

    The effective width is about 2a, and it is also limited by the edge and the next bolt. Prying is not added.

    No bolt is in tension.
  2. φ fy t² / 4

    Utilisation of the provided thickness.

    util 0.00

Detailing checks

Hole clear of the column and weld73.0 mm at T121.0 mmPASS

Centre to steel, including the weld leg beyond the profile.

Washer clear of the column and weld73.0 mm at T130.0 mmPASS

Washer outside diameter must sit outside the weld toe.

Nut clear of the column73.0 mm at T120.8 mmPASS

Across-corners of the hexagon nut against the column face.

Socket clearance to the column73.0 mm at T125.0 mmPASS

Typical 6-point socket outside diameter. Installation only.

Clearance to the flange face73.0 mm30.0 mmPASS

Perpendicular distance outside the flange, for bolts in line with the flange. Negative means the centre is inside the depth.

Clearance to the flange tipBolts are inboard of the tipsInboard of the tipPASS

A bolt past the flange tip has to clear the tip by the washer and the weld. A bolt inboard of the tip does not clash with it.

Clearance to the web115.5 mm30.0 mmPASS

Distance to the web rectangle. The middle bolt of a 2×3 fails this when it sits beside the web.

Minimum edge distance60.0 mm at T136.0 mm (1.50 df)PASS

AS 4100:2020 cl. 9.5.2. The selector sets 1.75, 1.50 or 1.25 df. An oversize hole is measured from the hole edge plus df/2.

Maximum edge distance60.0 mm150.0 mmPASS

AS 4100:2020 cl. 9.5.3: lesser of 12 t and 150 mm. Warning only.

Minimum bolt pitch160.0 mm (T1–T2)60.0 mm (2.5 df)PASS

AS 4100:2020 cl. 9.5.1.

Maximum pitch along a row160.0 mm200.0 mmPASS

AS 4100:2020 cl. 9.5.3 applies to the pitch along a row, not to the row spacing across the column. Warning only.

Washer clash between bolts160.0 mm44.0 mmPASS

Centre distance compared with the washer outside diameter.

Nut clash between bolts160.0 mm41.6 mmPASS

Centre distance compared with the nut across corners.

Socket clearance between bolts160.0 mm45.8 mmPASS

Room to put a socket on one nut while the next nut is in place.

Plate covers the column and the weld360 × 520 mm270 × 270 mmPASS

The plate has to be larger than the section footprint plus the weld leg on every side.

Anchor hole26 mm standardPlate washer if the hole is oversizePASS

An oversize anchor hole needs a plate washer. Bolt bearing shear is then unreliable until the washer and plate bear.

Shear through the grout35 mm grout, 7.55 kN per boltFriction or a shear lugWARN

The bolts carry shear across the grout, so the anchors bend. Friction on the grout, or a shear lug, avoids that. Neither is designed here.

Anchorage of the bolts into the concrete is not checked. Design it separately to AS 5216.

Glossary
1
AS 4100 builds the AS/NZS 1170.0 cl. 4.2.2 set from G, Q and Wu: 1.35G, 1.2G+1.5Q, 1.2G+Wu+ψcQ and 0.9G+Wu, and the same set with the wind sign reversed. The factors are editable.
2
Positive axial load compresses the plate onto the grout. X-X is the strong axis, parallel to the flanges and to the bolt rows. Y-Y is the minor axis, along the web.
3
Bolt forces are the linear cracked section and the plastic rectangular block. The check uses the greater tension.
4
Ec is AS 3600-2018 Table 3.1.2 for f'c from 20 to 65 MPa, interpolated between 20, 25, 32, 40, 50 and 65. Es = 200 000 MPa.
5
Linear bearing is P/A ± M y / I while the whole plate stays in compression. A no-tension triangle is used while the resultant is still inside the plate. Bolts are added only once that no-tension block cannot balance the load. They are then the bolts outside the compression zone, each with area (Es/Ec) As.
6
Plastic bearing follows AISC Design Guide 1. For compression, the centred rectangle is used until e exceeds e_crit. Past e_crit, and under net uplift with a moment, a rectangular block at the bearing strength is solved with the bolts: T = C − P. A biaxial case uses the larger uniaxial mechanism. If that quadratic has no root, the elastic forces are used.
7
Concrete bearing is AS 3600-2018 cl. 12.6: φ 0.60 × 0.90 f'c √(A2/A1), and the stress before φ is capped at 1.8 f'c. The square root is an input, default 1.
8
AS 4100 bolt shear uses the core area, with krd = 0.83 for grade 10.9 and threads in the shear plane, otherwise 1.
9
Shear is shared equally by the bolts. Friction is not credited. Shear through a grout layer bends the anchors; the detailing list warns and points to friction or a lug.
10
Plate bending from bearing uses m, n and λn'. An SHS uses 0.95d and 0.95b. The plate across the inside of the tube is not checked. Bolt tension uses a 45° width, about 2a, limited by edges and spacing. Prying is not calculated. The optional yield line is a Design Guide 1 style mechanism, mp = T a / (w + 2a), not an AS 4100 clause.
11
The fillet is one run around the section profile and is checked for the full action on each combination. kr = 1. Direct bearing under the column is not deducted.
12
Fillets of the rolled section are omitted from the outline and from the weld length.
13
Nut across-corners, washer outside diameter and a typical socket diameter are clearance checks, not capacities.

IQEG · Sydney · info@iqeg.com.au · 0433 597 205 · Investigate. Understand. Solve.

Rev 1.05 indicative calculation. Not certified engineering advice. Check mill tables and the current Standard.